So sánh DC-UPS

DC-UPS 12-24 Vdc 12 Vdc 24 Vdc 48 Vdc
Model CBI2801224A CBI123A CBI6012A CBI126A CBI1210A CBI1235A CBI6024A CBI243A CBI245A CBI2410A CBI2420A CBI485A CBI4810A
Output 12/24Vdc 12Vdc 12Vdc 12Vdc 12Vdc 12Vdc 24Vdc 24Vdc 24Vdc 24Vdc 24Vdc 48Vdc 48Vdc
15/10A 3A 5A 6A 10A 35A 2.5A 3A 5A 10A 20A 5A 10A
280W 36W 60W 72W 120W 420W 60W 72W 120W 240W 500W 240W 500W
OUTPUT DATA Output Vdc / IN 12Vdc, 15A 24Vdc, 10A 12Vdc, 3A 12Vdc, 5A 12Vdc, 6A 12Vdc, 10A 12Vdc, 35A 24Vdc, 2.5A 24Vdc, 3A 24Vdc, 5A 24Vdc, 10A 24Vdc, 20A 48Vdc, 5A 48Vdc, 10A
Efficiency (50% of ln) >91% ≥ 90% >90% ≥ 90% ≥ 90% >91% >90% ≥ 90% ≥ 90% ≥ 83% >91% ≥ 83% > 90%
LOAD OUTPUT Output voltage (at ln) Vdc 10-14.4Vdc (15.5Vdc Ni-Cd) 22-28.8Vdc (31Vdc for Ni-Cd) 10 -14.4Vdc (17Vdc Ni-Cd) 22 - 28.8Vdc (31Vdc Ni-Cd) 44 - 57.6Vdc (62Vdc Ni-Cd)
Continuous current (with battery) lload = ln 15A-12Vdc 10A-24Vdc 3A 5A 6A 10A 35A 2.5A 3A 5A 10A 20A 5A 10A
Max continuous current (with battery) lload = ln + lbatt 30A-12Vdc 20A-24Vdc 6A 10A 12A 20A 70A 5A 6A 10A 20A 40A 10A 20A
Max current Output Load: (Main Input) lload (4sec.) 45A-12Vdc 30A-24Vdc 9A max 15A 18A max  30A max  105A max 7.5A max 9A max 15A max 30A max 60A max 15A max 30A max
Max current Output Load: (Back Up) lload (4sec.) 30A-12Vdc 20A-24Vdc 6A max 10A 12A max 20Amax 70A max 5A max 6A max 10A max 20A max 40A max 10A max 20A max
Start from Battery only, without main ✔1 ✔1
Time Buffering ✔2 ✔2 ✔2 ✔2 ✔2 ✔2 ✔2
BATTERY OUTPUT Fast Charge - Boost Charge  14.4Vdc / 28.8Vdc (2.4V/Cell) 14.4Vdc (2.4V/Cell); Nicd 1.5V/cell 28.8Vdc (2.4V/Cell); Nicd 1.5V/cell 57.6Vdc (2.4V/Cell); Nicd 1.5V/cell
Max. Time Boost/Fast charge (Typ. at IN) 15h
Max. time Bulk Charge (Typ. at IN) 15h
Float Change: Depend on Battery type (V cell) 2.23 V/cell Open Lead, 2.25 V/cell Sealed Lead, 2.27 V/cell Sealed Lead, 2.3 V/cell gel; NiCd 1.5V/cell (10 elem.) Float (Imax 10%)
Recovery Charge 2-10V / 2-20V 2-9V 2-24V
Charging Current Limiting IN (ladj) 10÷100% / Ibatt 20÷100% / Ibatt 10÷100% / Ibatt 20÷100% / Ibatt 10÷100% / Ibatt
Remote Input Control (AMP Type connector) Bulk / Float
Charging Curve IUoU, Automatic, 4 stage
SIGNAL OUTPUT (RELAY) Main or Backup Power
Low Battery / Device Fault
AUXILIARY OUTPUT UPS Enabling
Communication Protocol Modbus RTU Ethernet / Can Modbus RTU Ethernet / Can Modbus RTU Modbus RTU
CLIMATIC DATA Ambient Temperature operation -25 ÷ +70°C
De rating Ta > (ln) > 50° -2.5%(In) / °C
Ambient Temperature Storage -40 ÷ +85°C
Humidity at 25 °C 95% to 25°C
Cooling Auto Convection
GENERAL DATA Isolation Voltage (IN / OUT) 3000Vac
Isolation Voltage (IN / PE) 1605Vac
Isolation Voltage (OUT / PE) 500Vac
Protection Class (EN/IEC 60529) IP 20
Reliability (MTBF IEC 61709) > 300 000 h
Dimension (w-h-d) 110x115x135 65x115x135 70x91x57 65x115x135 150x115x135 70x91x57 65x115x135 100x115x135 150x115x135 100x115x135 150x115x135
Safety Standard Approval CE cURus CE cURus cURus cURus CE cURus cURus cURus cURus cURus cURus
OPTIONAL ADEL View Graphic (Display 2.7”)
ADEL View Graphic (Display 3.5”)
ADEL View System (Sw for PC; Cloud)
Battery temp. compensation Probe RJTemp; 2 m length
(1) Options to be defined by Order/S (ex: CBIXXXA/S, push Button not available
(2)  Yes if required by order /TB1/TB2/TB3..
(3)  UL60950
Optional for auxiliary Output: Temp Charging probe 1m or 3m lenght. Remote monitoring Optional for auxiliary Output: Temp Charging probe 1m or 3m lenght. Remote monitoring Display. Modbus/Can Bus Cable. Paralleling Cable.